BMeters IWM-MB4 Wired M-BUS Module for WDE-K50 Water Meters

BMeters

BMeters IWM-MB4 Wired M-BUS Module for WDE-K50 Water Meters

Model IWM-MB4

Wired M-BUS communication module with a 1.5 m cable for pre-equipped WDE-K50 water meters with an inductive reading interface. Communicates to EN 13757-2/3, records alarms, reverse flow and leakage, IP68 housing, configured over NFC.

Prices on request. Contact us for availability and quotations.

Description

The IWM-MB4 is a wired M-BUS communication module for BMeters water meters supplied pre-equipped with an inductive reading interface, WDE-K50. It reads the meter inductively rather than magnetically, which closes the magnetic fraud path and makes the reading insensitive to pipe vibration.

Data is carried on a standard wired M-BUS bus to EN 13757-2/3 over a 1.5 m cable, so the module joins an existing M-BUS collection network alongside other meters. Besides the index it records alarms, reverse flow and leakage events, and it keeps measuring when bus voltage is absent, backed by a rechargeable lithium battery. The housing is protected to IP68 and the module is configured over NFC from an Android application.

It is used for centralised consumption monitoring and billing in residential blocks, commercial buildings, industrial sites and utility networks. Maximum reading error is 0.5 % and the permissible ambient temperature is +1 to 50 °C.

When ordering, confirm that the meter is the pre-equipped version with the inductive interface and state the meter model and size. The module for the GMDM-I series is the IWM-MB3.

Specifications

Product Type Wired M-BUS communication module
Communication Protocol M-BUS to EN 13757-2/3
Compatible Meter Models WDE-K50
Cable Length 1.5 m
Reading Interface Inductive; resists magnetic fraud and pipe vibration
Recorded Data Consumption, alarms, reverse flow and leakage events
Power Supply Rechargeable lithium battery
Backup Function Measurement continues without bus voltage
Ingress Protection IP68
Ambient Temperature Range +1 to 50 °C
Maximum Reading Error 0.5 %
Configuration Method NFC, via Android application
Order Code GM-BMETER-IWM-MB4