WIKA HP-2 Ultra High-Pressure Sensor – up to 15,000 bar (217,500 psi), 4–20 mA / 0–10 V, M16/M20 Sealing Cone, Stainless Steel

WIKA

WIKA HP-2 High-Pressure Sensor – Up to 15,000 bar

Model HP-2

WIKA model HP-2 pressure sensor for the highest pressures, with measuring ranges from 0…1,600 bar to 0…15,000 bar [217,500 psi]. Stainless steel 1.4534 wetted parts, 60° sealing-cone connections, and 4…20 mA, DC voltage or USB 2.0 output.

Prices on request. Contact us for availability and quotations.

Documents

Need a certificate we have not listed? Ask us and we will send it.

Description

The WIKA model HP-2 is a pressure sensor built for the highest pressure ranges. Measuring ranges run from 0…1,600 bar to 0…15,000 bar [0…23,000 to 0…217,500 psi], with overload safety and burst pressure tabulated for each range — for example 15,500 bar overload and 16,000 bar burst on the 0…15,000 bar range. Typical duties are test benches, water-jet cutting and high-pressure cleaning.

Maximum measured error is ≤ ±0.5 % of span, with an optional ≤ ±0.25 % for ranges up to and including 0…10,000 bar; on the 0…12,000 and 0…15,000 bar ranges ≤ ±0.5 % of span is typical. Long-term stability is ≤ 0.1 % of span per year. Output is 4…20 mA two-wire, DC 0…5 V or DC 0…10 V three-wire, or a USB 2.0 digital output adjusted through WIKA's EasyCom 2011 software.

Three versions are offered: the HP-2-S standard sensor; the HP-2-D fitted with DIPS, a diaphragm impact protection system that guards against cavitation and micro-diesel effects and which WIKA particularly recommends for water; and the HP-2-E fitted with EPC, an exchangeable pressure connection that allows the process connection to be changed without replacing the whole sensor, recommended where hairline cracks can occur. Wetted parts are stainless steel 1.4534. Medium temperature is 0…+80 °C and ambient -20…+80 °C.

When ordering, state the measuring range, the accuracy option, the process connection — M16 × 1.5 or 9/16-18 UNF female to 7,000 bar, M20 × 1.5 female to 15,000 bar, all with a 60° sealing cone — the output signal, and whether the DIPS version is required. Note that the permissible pressure at the installation point also depends on the high-pressure pipework used.

Specifications

Measuring Range 0…1,600 to 0…15,000 bar [0…23,000 to 0…217,500 psi]
Accuracy Max. measured error ≤ ±0.5 % of span; ≤ ±0.25 % of span optional for ranges to 0…10,000 bar (per IEC 61298-2). On the 0…12,000 and 0…15,000 bar ranges ≤ ±0.5 % of span is stated as typical
Long-Term Stability ≤ 0.1 % of span/year (per DIN 16086); ≤ 0.2 % of span/year for special ranges
Output Signal 4…20 mA (2-wire); DC 0…5 V and DC 0…10 V (3-wire); USB 2.0
Power Supply DC 10…30 V (4…20 mA and 0…5 V); DC 14…30 V (0…10 V); DC 5 V (USB 2.0)
Process Connection M16 × 1.5 female with 60° sealing cone (to 7,000 bar); M20 × 1.5 female with 60° sealing cone (to 15,000 bar); 9/16-18 UNF female with 60° sealing cone (to 7,000 bar)
Wetted Material Process connection and sensor stainless steel 1.4534; Elgiloy measuring cell optional on selected ranges
Versions HP-2-S standard; HP-2-D with DIPS diaphragm impact protection system against cavitation and micro-diesel effects; HP-2-E with EPC exchangeable pressure connection
Ingress Protection IP65 (angular connector DIN 175301-803 A); IP67 (M12 × 1 and cable outlet); IP67 instrument / IP20 connector with USB type A
Medium Temperature 0…+80 °C [32…176 °F]
Ambient Temperature -20…+80 °C [-4…+176 °F]