WIKA MG-1 Pressure Sensor for Medical Pipeline Services & Oxygen

WIKA

WIKA MG-1 Pressure Sensor for Medical Pipeline Services & Oxygen

Model MG-1

WIKA model MG-1 pressure sensor for medical pipeline services and oxygen service, supplied oil- and grease-free to ISO 15001 or ASTM G93 cleanliness levels. Ranges 0…6 to 0…400 bar, 4…20 mA or DC voltage output, 316L case and IP67 protection.

Prices on request. Contact us for availability and quotations.

Documents

Need a certificate we have not listed? Ask us and we will send it.

Description

The WIKA model MG-1 is a pressure sensor for medical pipeline services and for oxygen service. It is manufactured and packed to defined cleanliness levels, and the wetted parts are supplied oil- and grease-free.

Measuring ranges are 0…6, 0…10 and 0…16 bar and 0…200, 0…300 and 0…400 bar [0…100 to 0…5,000 psi], also available in kg/cm², MPa and kPa, with vacuum and ± ranges available; the sensor is vacuum tight. Accuracy at reference conditions is ≤ ±2 % of span, non-linearity ≤ ±0.5 % of span BFSL, long-term drift ≤ 0.3 % of span per year and settling time ≤ 2 ms.

Four cleanliness levels are offered with three packaging variants: breathing media (oil and grease free, residual hydrocarbons < 1,000 mg/m²), medical standard per ISO 15001 (< 550 mg/m² below 30 bar, < 220 mg/m² above), industrial standard per ASTM G93 level D/E, and high industrial standard per ASTM G93 level C (< 66 mg/m²). Wetted parts are stainless steel 316L and 13-8 PH with an FKM sealing ring where one is fitted, and the case is stainless steel 316L.

Ingress protection is IP67, and the permissible ambient and medium temperature range is -20…+70 °C. When ordering, state the measuring range and unit, the output signal with its matching supply voltage, the process connection, the electrical connection (M12 × 1 circular connector or 2 m cable outlet) and the required cleanliness level and packaging.

Specifications

Measuring Range 0…6, 0…10, 0…16 bar and 0…200, 0…300, 0…400 bar [0…100 to 0…5,000 psi]
Accuracy ≤ ±2 % of span at reference conditions; non-linearity ≤ ±0.5 % of span BFSL per IEC 61298-2
Long-Term Drift ≤ 0.3 % of span/year (per IEC 61298-2)
Output Signal 4…20 mA (2-wire); DC 0…10 V, 0…5 V, 1…5 V (3-wire); DC 0.5…4.5 V ratiometric
Power Supply DC 8…30 V (4…20 mA, 0…5 V, 1…5 V); DC 14…30 V (0…10 V); DC 5 ±0.5 V (ratiometric)
Wetted Material Process connection stainless steel 316L and 13-8 PH; FKM sealing ring where fitted
Case Material Stainless steel 316L; electrical connection glass-fibre reinforced PBT GF 30
Process Connection G⅛B and G¼B (EN 837); G¼A (DIN 3852-E); ⅛ NPT and ¼ NPT (ANSI/ASME B1.20.1); R¼ (ISO 7); ¼ PT; 7/16-20 UNF-2A O-ring boss (SAE)
Cleanliness Breathing media: oil and grease free, residual hydrocarbons < 1,000 mg/m²; medical standard per ISO 15001 (< 550 / < 220 mg/m²); industrial per ASTM G93 level D/E; high industrial per ASTM G93 level C (< 66 mg/m²)
Ingress Protection IP67 per IEC 60529
Temperature Range Medium and ambient -20…+70 °C [-4…+158 °F]; storage -25…+80 °C