WIKA PGT23.100 / PGT23.160 – Bourdon Tube Pressure Gauge with Electrical Output (intelliGAUGE®)

WIKA

WIKA PGT23.100 / PGT23.160 intelliGAUGE with 4-20 mA Output

Model PGT23.100 / PGT23.160

Stainless steel Bourdon tube pressure gauge with an integrated electrical output signal: local mechanical indication that stays readable without power, plus 4-20 mA transmission to the control room from one instrument.

Prices on request. Contact us for availability and quotations.

Documents

Need a certificate we have not listed? Ask us and we will send it.

Description

The WIKA PGT23 intelliGAUGE combines a mechanical Bourdon tube pressure gauge with integrated electronic signal processing. The pointer is driven mechanically, so the process pressure can still be read on site if the supply voltage is lost, while an electronic angle encoder - non-contact, and therefore free of wear and friction - determines the pointer shaft position and generates the output signal.

The instrument is based on WIKA's model 23x.30 stainless steel safety gauge and is built to EN 837-1 with an S3 safety case: solid baffle wall and blow-out back. The case is stainless steel 1.4301 (304), the window laminated safety glass or polycarbonate, and the wetted process connection and Bourdon tube are stainless steel 1.4404 (316L). WIKA names the chemical and petrochemical industries, hydrocarbon processing, power generation and water and wastewater as the applications.

Nominal sizes are 100 and 160 mm with scale ranges of 0 ... 0.6 to 0 ... 1,600 bar (0 ... 10 to 0 ... 30,000 psi). The mechanical indication is accuracy class 1.0 per EN 837-3; the output signal is accurate to +/-1 % of span with a linearity error of no more than 1 % by the terminal method. Four output variants are offered: 4 ... 20 mA 2-wire passive per NAMUR NE 43, 4 ... 20 mA 2-wire for hazardous areas, 0 ... 20 mA 3-wire and 0 ... 10 V 3-wire.

Ingress protection is IP54 for unfilled instruments and IP65 or IP66 otherwise - case filling with silicone oil M50 raises it to IP65. When ordering, specify nominal size, scale range, process connection, output variant and supply voltage, and note that the NS 63 instrument is a different model, PGT23.063, covered by data sheet PV 12.03.

Specifications

Standard EN 837-1 and ASME B40.100; case safety level S3 per EN 837-1 with solid baffle wall and blow-out back
Nominal Size (NS) Ø 100 mm [4"] and Ø 160 mm [6"]
Scale Range 0 ... 0.6 to 0 ... 1,600 bar [0 ... 10 to 0 ... 30,000 psi]; vacuum and compound ranges available
Accuracy (indicator) Class 1.0 per EN 837-3; +/-1 % of measuring span per ASME B40.100 (grade 1A)
Accuracy (output signal) +/-1 % of measuring span; linearity error <= 1 % (terminal method); resolution 0.13 % FS; long-term stability < 0.3 % FS per year; measuring rate 100 per minute
Output Signal Variant 1: 4 ... 20 mA, 2-wire, passive, per NAMUR NE 43. Variant 2: 4 ... 20 mA, 2-wire, for hazardous areas. Variant 3: 0 ... 20 mA, 3-wire. Variant 4: 0 ... 10 V, 3-wire
Power Supply Variants 1 and 3: DC > 12 to <= 30 V. Variant 2: DC > 14 to <= 30 V. Variant 4: DC > 15 to <= 30 V. Load for variants 1-3: RA <= (UB - 12 V)/0.02 A, max. 600 ohm
Wetted Materials Process connection and Bourdon tube stainless steel 1.4404 (316L)
Process Connection G 1/4 B, G 3/8 B, G 1/2 B, M12 x 1.5, M20 x 1.5 (EN 837-1); R 1/4, R 3/8, R 1/2 (ISO 7); 1/4 NPT, 3/8 NPT, 1/2 NPT (ANSI/B1.20.1); lower or lower back mount
Medium Temperature -20 ... +100 °C, -20 ... +120 °C or -20 ... +150 °C depending on version; ambient -20 ... +60 °C (-40 ... +60 °C only with silicone oil case filling)
Ingress Protection IP54, IP65 or IP66 per IEC/EN 60529; IP54 only for unfilled instruments, IP65 for instruments with case filling